S type load cell can be used both for tension and compression method. S type load cell is used for the small capacity testing facility, hopper scales, electronic scale, riveting machine, welding machines, cold & hot pressure film machine and other weighing systems. It is simple for installation and has a full range of capacities.

Send Inquiry


Product Features:

Alloy steel /stainless steel material optional, potted or laser sealing
Simple to install, full range of capacities
Good output symmetry, compact structure
Both tension and compression can be used for weighing

s type load cell 5

Product Parameters:

S type load cell ZH-ST1

Capacity 0.005~20t Material Alloy steel/stainless steel
Rated Output(mV/V) 2.0 ± 0.005 Nonlinearity ±0.02%FS
3.0 ± 0.005
Hysteresis ±0.02%FS Repeatability ±0.01%FS
Creep(30 minutes) ±0.02%FS Zero balance ±1.00%FS
Temperature effect on zero ±0.02%F.S./10℃ Temperature effect on output ±0.02%F.S./10℃
Input resistance(Ω) 385±10 Output resistance(Ω) 350±3
Insulation resistance ≥5000MΩ Excitation voltage 5V-10V(DC)
Compensated temperature range -10~+50℃ Operating temperature range -20~+60℃
Safe overload 120%FS Breaking loading 150%FS
Cable Φ 5.4 X 5 M Cable color code Input: red+ black-
Or customized by request Output: green+ white-

S type load cell ZH-ST2

Capacity 1~20t Material Alloy steel/stainless steel
Rated Output(mV/V) 2.0 ± 0.005 Nonlinearity ±0.02%FS
Hysteresis ±0.02%FS Repeatability ±0.01%FS
Creep(30 minutes) ±0.02%FS Zero balance ±1.00%FS
Temperature effect on zero ±0.02%F.S./10℃ Temperature effect on output ±0.02%F.S./10℃
Input resistance(Ω) 385±10 Output resistance(Ω) 350±3
Insulation resistance ≥5000MΩ Excitation voltage 5V-10V(DC)
Compensated temperature range -10~+50℃ Operating temperature range -20~+60℃
Safe overload 120%FS Breaking loading 150%FS
Cable Φ 5.4 X 5 M Cable color code Input: red+ black-
Or customized by request Output: green+ white-

Application and After-Sales Service: